QPGo.X

QPGo.X Single-phase Complete Pump (1x220-230V / 50 Hz)

4” complete pump made of ZDS stainless steel hydraulic part, 2-wire single-phase oil-cooled O2 motor and supply cable (different lengths available). These complete submersible pumps, manufactured to ISO 9001 standards, are available up to the maximum delivery of 11.000 l/h and 220 m head. The O2 motor does not require a start and run control box, as the capacitor is built into it. The QPGo.X complete pumps are designed to be used in the following applications: lifting, distribution, and pressurisation in civil and industrial water systems, garden irrigation systems, filling of pressure vessels and tanks, fire-fighting systems and washing systems, drainage systems, fountains supply.

Send us a request


  • kW: 0,37 - 1,5
  • Voltage range: 1x220-230V / 50Hz
  • Voltage tolerance 50Hz from nominal: +6% / -10% Un
  • Degree of protection: IP 68
  • Maximum quantity of suspended sand: 600 g/m³
  • Insulation: F
  • Rated ambient temperature: max 40° C
  • Cooling flow: min 8 cm/sec
  • Maximum starts/h: 150, equally distributed
  • Mounting: vertical/horizontal
  • Maximum delivery (Q): 11.000 l/h
  • Maximum head (H): 220 m
  • Maximum immersion depth: 150 m
  • Outlet diameter: 1" ¼ G-F, 2" G-F
  • Allowed range of water pH: 6,4 - 8,0

Automatic protections

Thermal protection

Thermal protection

The QPGo.X complete pump is automatically protected against motor overheating. This can happen because of: the high temperature of the pumped liquid; when the minimum distance between the pump installed and the well bottom isn’t respected; when the pump is installed in well/tanks bigger than 4” without a proper cooling system; when the pump works in shut-off.

Current overload protection

Current overload protection

The QPGo.X complete pump is protected against against overload. In case the pump is partially or totally blocked, it automatically restarts as soon as the correct working temperature parameters are restored.

Model performance

Download

Information on a proper installation

  • If you are using a generator with an internal combustion engine, it is necessary that the generator’ s power measured in kW (in continuous delivery) is three times the rated power in kW of the submersible pump.
  • We recommend to install a proper cooling jacket in installations bigger than 10 cm, to guarantee the correct motor cooling flow.
  • In order to reset the thermal protections, disconnect the pump power, wait that the correct working temperature parameters are restored, then plug it in again.

Download our catalogue

To download the version with prices please login or register.